Took me 5 hours to find a ground fault in a panel because I skipped the obvious step
Last Tuesday I was at a house in Mesa doing a takeover on an old panel, and the thing kept showing a zone fault on the glass break loop. I checked every sensor, re-stripped connections, swapped the zone card, and even ran a jumper directly to the panel. After about 5 hours of crawling in the attic and pulling my hair out, I finally put a meter on the ground wire and saw 18 ohms of resistance. The actual problem was a corroded ground lug on the can, not a sensor or wiring issue at all. I had walked right past it three times because I assumed the panel was grounded fine. Now I'm wondering how many other jobs I've made harder by not checking the basics first. Has anyone else had a ground issue throw a zone fault that sent you chasing ghosts?